PilotE² Heat Meter Portable

Código: PE2HMP01 Categorías: , , ,

Descripción

Portable heat meter with non-invasive ultrasonic flowmeter designed to measure the fluid speed flowing through a duct. The transducers are non-invasive, clamp-on type, allowing easy installation and cleaning. It uses transit time difference measuring principle by two transducers that works as ultrasonic transmitters and receivers.

It also has two Pt100 temperature and three 4-20 mA analog inputs allowing it to work as a heat meter.

Main features

  • High Performance Flowmeter: ± 1% accuracy, ± 0.2% repeatability, ± 0.5% linearity, integration period 0.5s.
  • 8-36Vcc extended range power supply.
  • Rugged carrying case IP67 suitable for indoor and outdoor applications.
  • Standard wiring system M8 and M12.
  • Ultrasonic transducers for flow measurement.
  • 2 Pt100 temperature inputs for heat meter.
  • 3 4-20mA analog inputs, two of which can be temperature transducers for heat meter.
  • RS485 port with Modbus communications protocol.
  • 4-20mA analog output.
  • OCT output and relay output with programmable pulse width.
  • Internal storage flash memory to store configuration parameters.
  • Total volume and energy (positive, negative and net).
  • Monitoring by PilotE² Heating Analyzer using RS485 communication bus. You can connect multiple serial devices sub-metering.

Supplied Equipment

  • Electronic unit, portable heat meter with non-invasive ultrasonic flowmeter. IP67 rating closed, IP65 rating openend.
  • Rugged carrying case with integrated trolley, waterproof and impact resistant. IP67 rating.
  • A pair of ultrasonic transducers for 15 mm OD – 100 mm OD  pipes with 5m shielded twisted cable. IP68 rating.
  • A pair of ultrasonic transducers for 50 mm OD – 700 mm OD pipes with 5m shielded twisted cable. IP68 rating.
  • A pair of stainless steel clamps to fix transducers.
  • A pair of releasable ties to fix temperature probes, (-40 °C to +85° C) continuous, (+105 °C for 500 h) .
  • A pair of contact temperature probes, Pt100 3 wire, connector M8, class A.
  • Wiring 10m cable with M12 sockets for supply and communications.
  • Silicon grease coupler tube.

Accessories

  • A pair of ultrasonic transducersfor 50 mm OD – 700 mm OD pipes with 5m shielded twisted cable. IP68 rating.
  • Temperature sensor with active 4-20mA output with or without LCD display, immersion or contact. IP65 rating.
  • Temperature sensors with passive Pt100 output, immersion or contact.
  • Installation material for sensors.
  • Pressure sensors with active 4-20mA output with or without LCD display.
  • Thickness gauge to increase measurement accuracy.