PilotE² Heat Meter Portable

You Are Here: Inicio / Measurement / Heat/Cool / PilotE² Heat Meter Portable

Portable heat meter with non-invasive ultrasonic flowmeter designed to measure the fluid speed flowing through a duct. The transducers are non-invasive, clamp-on type, allowing easy installation and cleaning. It uses transit time difference measuring principle by two transducers that works as ultrasonic transmitters and receivers.

It also has two Pt100 temperature and three 4-20 mA analog inputs allowing it to work as a heat meter.

Main features

  • High Performance Flowmeter: ± 1% accuracy, ± 0.2% repeatability, ± 0.5% linearity, integration period 0.5s.
  • 8-36Vcc extended range power supply.
  • Rugged carrying case IP67 suitable for indoor and outdoor applications.
  • Standard wiring system M8 and M12.
  • Ultrasonic transducers for flow measurement.
  • 2 Pt100 temperature inputs for heat meter.
  • 3 4-20mA analog inputs, two of which can be temperature transducers for heat meter.
  • RS485 port with Modbus communications protocol.
  • 4-20mA analog output.
  • OCT output and relay output with programmable pulse width.
  • Internal storage flash memory to store configuration parameters.
  • Total volume and energy (positive, negative and net).
  • Monitoring by PilotE² Heating Analyzer using RS485 communication bus. You can connect multiple serial devices sub-metering.

Supplied Equipment

  • Electronic unit, portable heat meter with non-invasive ultrasonic flowmeter. IP67 rating closed, IP65 rating openend.
  • Rugged carrying case with integrated trolley, waterproof and impact resistant. IP67 rating.
  • A pair of ultrasonic transducers for 15 mm OD – 100 mm OD  pipes with 5m shielded twisted cable. IP68 rating.
  • A pair of ultrasonic transducers for 50 mm OD – 700 mm OD pipes with 5m shielded twisted cable. IP68 rating.
  • A pair of stainless steel clamps to fix transducers.
  • A pair of releasable ties to fix temperature probes, (-40 °C to +85° C) continuous, (+105 °C for 500 h) .
  • A pair of contact temperature probes, Pt100 3 wire, connector M8, class A.
  • Wiring 10m cable with M12 sockets for supply and communications.
  • Silicon grease coupler tube.

Accessories

  • A pair of ultrasonic transducersfor 50 mm OD – 700 mm OD pipes with 5m shielded twisted cable. IP68 rating.
  • Temperature sensor with active 4-20mA output with or without LCD display, immersion or contact. IP65 rating.
  • Temperature sensors with passive Pt100 output, immersion or contact.
  • Installation material for sensors.
  • Pressure sensors with active 4-20mA output with or without LCD display.
  • Thickness gauge to increase measurement accuracy.
Peso 9.7 kg
Dimensiones 559 × 355 × 229 mm

No hay reseñas todavía.

Sé el primero en opinar “PilotE² Heat Meter Portable”

Código: PE2HMP01. Categorías: , , , .

Uso de cookies

Este sitio web utiliza cookies para que usted tenga la mejor experiencia de usuario. Si continúa navegando está dando su consentimiento para la aceptación de las mencionadas cookies y la aceptación de nuestra política de cookies, pinche el enlace para mayor información.

ACEPTAR
Aviso de cookies